3.9
2024-02-14
• If "Enhancements" are set to "Off", loading an empty card will blink "0.00" and program memory will be cleared to NOPs, like on a real HP-65.
• Some fonts have been changed from Courier to Menlo for better legibility.
• Screens "Paper Tape Printer", "Program Usage", and "Program Description" may be dismissed by dragging them down, in addition to swiping them horizontally.
3.7.6
2023-09-18
• Backstepping from step 001 to 000 in modes UI and Plus is now supported. In addition, step 000 is labeled as "[TOP]".
• In vintage mode, typing "GTO.digit" and "LBL.digit" would not start a number entry.
• Also in vintage mode, single-stepping an instruction like LBL 5 would not be executed as on a real HP-65 when the mode switch was flipped to W/PRGM and back to RUN between steps "LBL" and "5".
[Thanks, Vincent]
3.7
2023-05-13
• Enable or disable the flashing of pressed keys in the Settings ("Flash Keys").
• In enhanced modes ("UI" and "Plus"), the trigonometric mode indicator DEG appears only when "High Contrast" is on. No indicators are shown in vintage modes ("Off" and "Fast").
Bug fixes:
• [Vintage mode] Entering a merged code instruction (e.g. g NOP) at step 100 now works correctly.
• [Vintage mode] Single-stepping (SST) from step 100 in W/PRGM mode now shows 00 00, not step 01.
3.5
2021-11-30
• Improved compatibility of Data Cards across the different Enhancements settings of the calculator. (Thanks, Matt!)
• Clearing registers now affects register R0 in Plus mode only.
• Small cosmetic changes
Bug fix:
• Fixed wrong step 75 in MATH 1-15A in the default database from 99 to 03
3.2
2020-04-08
• Delete a range of program steps (x,y) by executing DEL in RUN mode
• The command "clear all extended registers" (f CLx) brings up a warning dialog
• Key flashing may be turned off and on:
- Store 19390101 in R1 to turn off
- Recall 19390101 from R1 to turn on
(Hewlett-Packard Company was founded on Jan 1, 1939)
3.1
2020-03-17
• Added comparison instructions x < y and x < 0 in Plus mode
• Improved listing in Vintage mode
Bug fix:
• Using scientific notation could crash the app in some regions, i.e. Australia, Sweden, Slovenia.
3.0
2020-01-22
• Swiping left the card slot area shows program listing
• In the program listing, unused label names appear in gray
• Improved compatibility of vintage mode with a real HP-65
• Detail view of Card Manager shows calculator mode (RUN or W/PRGM, top-left)
• Support for iOS 13: Dark Mode, file sharing
Check out the new Download walk-through on the website (under "Sharing".)
RPN-65 SD now requires iOS 11 or later.
2.5.1
2019-08-19
• Fixed an issue in vintage mode where in rare cases a random number would show instead of the result
• Fixed an issue in vintage mode where the step number was not correctly updated in W/PRGM mode
2.5
2019-08-16
• Card texts for vintage mode cards were not centered on some devices
• Fixed a few inconsistencies occurring in vintage mode only
2.4
2016-11-17
• Backstepping all input digits is not logged as CLX in TRACE mode anymore
• Access RPN-65 homepage directly from info screen
• Many under-the-hood refinements
• Support of late 2018 iPhones
Bug fixes:
• After deleting a card, the first card would erroneously be selected
• D.MS operation didn't always convert 60 secs into 1 min