3.1.8
2021-03-04
Added ability to export log data from individual characteristics
3.1.5
2020-12-03
- Added UUID to advertisement logs to help differentiate between unnamed devices
- Bug fix for manufacture data parsing that was causing a crash on a small number of devices
3.1.2
2020-08-15
Sorry! We broke Dark mode in the last release. Fixed!
3.1.1
2020-08-12
- Minor bug fix and performance improvement
3.1.0
2020-08-11
Visual:
- Darker dark mode!
- Quick Launch button now includes easy access to Filter and Sort
- Refined table views
Bug fixes:
- Fixed bug causing the Gatt Discovery popup to stay on screen in some situations forcing app restart
- General performance improvements to connection process
3.0.11
2020-06-10
- Bug fix for problem where there was no way to return to GATT view from an individual characteristic view on iPads
3.0.10
2020-05-21
- Sizing updates to better accommodate the new iPhone SE
- Updated advertising data format to improve readability
- Minor style revisions for dark mode
- Revised descriptor view to improve usability
3.0.9
2020-01-23
- Added support for iOS versions back to iOS11
3.0.8
2019-12-20
- Fixed bug causing app to crash when using the search function in some situations
- Add tutorial for performing Device Firmware Upgrades
3.0.6
2019-12-01
- Added DFU support for Nordic Semiconductor devices (nRF51, nRF52)
- Automatic reconnection after performing DFU update
- We are planning on adding DFU support for additional manufacturers, send us an email (Setting tab) and let us know who you would like us to add next
3.0.5
2019-11-13
- Refresh scan no longer clears connected devices. When you refresh the scan results, any devices that are currently connected will be moved to the top and new scan results will be added below
- Fixed bug where notifications were shown as disabled when previously enabled
- Fix bug where descriptor values were not displayed
- Add "Read" button to manually read descriptors. Some devices (looking at you microbit) become unresponsive after reading descriptors so we have stopped reading descriptors automatically and instead give you control to read them manually
- Add ability to disable RSSI updates in log data
- General bug fixes and performance improvements
3.0.4
2019-10-22
- Support for new screen presentation formats in iOS13
- Performance optimizations for GATT Discovery
- Fix GATT discovery timeout issue for large GATT profiles
- Fix logging Auto-Scroll bug causing log view to open in an unexpected position
3.0.3
2019-09-24
- Fix logging bug causing app to become unresponsive during high throughput data transfers
3.0.2
2019-09-18
- Fixed bug preventing scrolling after using the ascii or decimal keyboard
- Fixed layout issue on iPad causing space at the bottom of the discovery page
3.0.1
2019-09-16
- Added optional floating action button to control scanning
- Fix keyboard sizing issues that was occurring on some iOS12 devices
3.0.0
2019-09-14
Everything! Version 3.0 has been redesigned and rebuilt from the ground up! Full iPad support with enhanced layouts!
2.1.6
2018-03-14
-Added support for iPhone X
-Added estimated beacon interval
-Added increase characteristic write functionality with support for both ASCII and HEX
-Support for viewing all characteristic properties
-Added messages to display a reason for disconnections
-Improved log data readability
-General performance improvments
2.1.4
2017-06-21
What's New
-Revised settings menu layout to better accomodate all devices
-Add new filter to allow filtering devices based on RSSI!
-The number of devices found during scanning is now displayed in the Navigation Bar
-Added feature/support request link
General
-Removed a debug statement that was causing the app to lock up and crash in some situations
2.1.0
2017-05-17
-General bug fixes and performance improvements
2.0.9
2017-05-06
-Add visual RSSI indicator
-General bug fixes and performance improvements
2.0.8
2017-04-07
Fixed UI layout issue on smaller screens
2.0.7
2017-04-05
-Added continuous RSSI (signal strength) monitoring while scanning for peripherals.
-RSSI values for each of the peripherals displayed in the table are updated continuously while scanning is active.
-General Bug fixes and performance improvements
2.0.6
2017-03-18
Added raw data log view to the home view in Central Mode. General bug fixes and improvements
1.0.1
2017-02-10
Peripheral mode service and characteristic display bug fixes