SharpAngleApp

SharpAngleApp



R$ 19,90Best Deal Ever
4.0for iPhone, iPad and more
Age Rating
4+
Apps in this category do not contain restricted content.
9+
Apps in this category may contain mild or occasional cartoon, fantasy or real-life violence, as well as occasional or mild adult, sexually suggestive or horrifying content and may not be suitable for children under 9 years of age.
12+
Apps in this category may contain occasional mild indecent language, frequent or intense cartoon or real-life violence, minor or occasional adult or sexually suggestive material, and simulated gambling, and may be for children under 12 years of age.
17+
You must be at least 17 years old to access this App.
Apps in this category may contain frequent and intense offensive language; Frequent and intense cartoon, fantasy or realistic violence: frequent and intense adult, scary and sexually suggestive subjects: as well as sexual content, nudity, tobacco, alcohol and drugs, may not be suitable for children under 17 years of age.
SharpAngleApp Capturas de tela
SharpAngleApp CartazSharpAngleApp CartazSharpAngleApp CartazSharpAngleApp CartazSharpAngleApp CartazSharpAngleApp CartazSharpAngleApp CartazSharpAngleApp Cartaz
SharpAngleApp CartazSharpAngleApp CartazSharpAngleApp CartazSharpAngleApp CartazSharpAngleApp Cartaz

About SharpAngleApp

The diagnosis of hip dysplasia, the prognosis, the evaluation of different methods of treatment is based mainly on X-rays of the hip joint. For the objective evaluation of hip dysplasia in everyday orthopaedic care the acetabular index (AI) or the Centre-edge angle (CE) are frequent measured. But the measurement of AI is not valid index for acetabular Dysplasia in children over 8 years of age and in cases with subluxation of the femoral head where the centre-edge angle (CE) is not accurately calculated. The acetabular angle of Sharp (AA) is especially designed for theses cases. The acetabular angle of Sharp (AA) is formed by a horizontal line connecting the tips of the both pelvic teardrops and by a line connecting the inferior tip of the pelvic teardrop with the most lateral point of the acetabular roof.
Measuring angles in X-rays in clinical settings it is time consuming. Accessory instruments like protractors, goniometers, well sharped pencils, rulers or even transparent papers must be available in a busy everyday practice. Usually you miss or you never had one or another. Also after measurement you have to compare the data that you measure with the normal reference values according to patient age, and decide what could be considered normal in an X-ray of the hip and what is considered pathologic. This way is cumbersome and old fashioned. 
The SharpAngle app is medical software aimed for orthopaedic surgeons, providing tools that allow doctors to:
-Securely import medical images directly from the camera or stored photos
-Offers a very convenient way to determine the most accurate possibly lines in order to measure the angles. By the aid of a circular transparent template, the points of interest are marked accurately. The automatically formed lines, drawn between points, measure automatically the angles of interest. The results are printed in degrees. By inputing the age, of the patient in the App, the measured angle is compared with values from normal reference database according to patient age. In case the measured angle is beyond the normal range for that age, the hips are categorised as borderline dysplastic or dysplastic.
-Save the planned images, for later review or consultation.
All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! SharpAngle App is indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software. The software is not for primary image interpretation.
The app is a handy tool for an orthopaedic surgeon, radiologist, medical student or resident who wants objectively monitor and determine the severity of dysplasia of the hip. The build-in comparison feature with the normal reference values according to patient age may help decide what could be considered normal or borderline dysplastic or dysplastic. The app is not a simple goniometer, is an enhanced product which offers the ability to compare all the input data with medical reference database. The results are printed on the screen and the hips are categorised as normal or dysplastic according to the AA angle measures respectively. This feature it is particular useful especially in clinical settings where you need a quick results without losing time in looking for reference data according to age variations in huge textbooks.
Reference
1.Sharp IK. Acetabular dysplasia. The acetabular angle. J Bone Joint Surg Br 1961; 43B:268–272.
Show More

Novidades da Última Versão 4.0

Last updated on Apr 19, 2022
Versões Antigas
update for 14.5, bugs fixed.
Show More
Version History
4.0
Apr 19, 2022
update for 14.5, bugs fixed.
3.5
Jan 4, 2020
update for 13.2 iOS bug fixes and performance improvements plus dark mode support.
3
Dec 6, 2018
update for iOS 12.1
2.3
Jan 9, 2018
-x iphone update
-better graphics for ipad
2.0
Nov 4, 2017
-update for xphone
-fix bugs, better speed,better angle presentation
1.1
Oct 31, 2017
-bug fixed
1.0
Oct 13, 2017

Preço de SharpAngleApp

Hoje:
R$ 19,90
O Mais Baixo:
R$ 19,90
O Mais Alto:
R$ 54,90

SharpAngleApp FAQ

Clique aqui para saber como baixar SharpAngleApp em um país ou região restrita.
Confira a lista a seguir para ver os requisitos mínimos de SharpAngleApp.
iPhone
Requer o iOS 15.4 ou posterior.
iPad
Requer o iPadOS 15.4 ou posterior.
Mac
Requer o macOS 12.3 ou posterior.
iPod touch
Requer o iOS 15.4 ou posterior.
SharpAngleApp suporta Inglês

Vídeos Relacionados

Latest introduction video of SharpAngleApp on iPhone
Latest introduction video of SharpAngleApp on iPhone
Latest introduction video of SharpAngleApp on iPhone

Alternativa de SharpAngleApp

Você pode gostar

Obtenha mais de ORTHOPRACTIS.COM SINGLE MEMBER P.C.