CupAnteversionInclinationApp

CupAnteversionInclinationApp



HK$ 58.00

4.5for iPhone, iPad and more
ORTHOPRACTIS.COM SINGLE MEMBER P.C.
Developer
692.4 KB
Size
2022年11月10日
Update Date
Medical
Category
17+
Age Rating
Age Rating
4+
Apps in this category do not contain restricted content.
9+
Apps in this category may contain mild or occasional cartoon, fantasy or real-life violence, as well as occasional or mild adult, sexually suggestive or horrifying content and may not be suitable for children under 9 years of age.
12+
Apps in this category may contain occasional mild indecent language, frequent or intense cartoon or real-life violence, minor or occasional adult or sexually suggestive material, and simulated gambling, and may be for children under 12 years of age.
17+
You must be at least 17 years old to access this App.
Apps in this category may contain frequent and intense offensive language; Frequent and intense cartoon, fantasy or realistic violence: frequent and intense adult, scary and sexually suggestive subjects: as well as sexual content, nudity, tobacco, alcohol and drugs, may not be suitable for children under 17 years of age.
CupAnteversionInclinationApp 螢幕截圖
CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報
CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報CupAnteversionInclinationApp 海報

About CupAnteversionInclinationApp

In Total hip Arthroplasty the orientation, namely anteversion and inclination of the new acetabular component -cup- influences wear, range of movement (ROM), and the likelihood of dislocation after total hip replacement (THR). Evaluating objectively of the cup anteversion, and inclination in hip arthroplasty replacement surgery is of paramount importance. Radiographs are the most important diagnostic means in the follow-up for evaluation of a total hip arthroplasty. Measuring anteversion and inclination in everyday clinical setting is a cumbersome work for a medical doctor. Computation requires a calculator, which requires an additional effort during practice and slows down workflow.
The App is medical software aimed for orthopaedic surgeons, providing a tool that allow doctors to:
-Securely import medical images directly from the camera or stored photos.
-By marking certain anatomical landmark and points in a simple standard AP pelvic radiograph, values for cup inclination and anteversion are being calculated. The app is based on Widmer’s method which is the proven that is the most accurate compared to others.
-Pelvic tilt expressed by the angle APP is incorporated in measurements and can be adjusted manually according to surgeons preference.
-Radiographic Inclination (RI) and Radiographic Anteversion (RA) values are adjusted by taking into account pelvic tilt (APP angle).
- RI or RA values are printed in red or green, according to measured value in cases these are in certain range (Lewinnek at al), indicating if the positioning of the cup is optimal (green) or not (red).
-The data are printed over to screen so each case can easily assessed.
-For more accurate results the source of central ray of the x-ray should be at position at 1150mm away from x ray table .
-Save the planned images, for later review or consultation.
The app offers an easy way to quantify cup anteversion and inclination a quick and comfortable manner without the use of a goniometer or a ruler or to calculate elaborated formulas.
All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! The App is indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software.The software is not for primary image interpretation.
In a busy THA practice, the examiner to draw lines in X-rays, it is time consuming and cumbersome to calculate mathematics.This App is particular useful in clinical settings where you need a quick results without losing time. Please see tutorial videos at the developer’s web site www.orthopractis.com

Reference
1. Nomura T, Naito M, et al .An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs. Bone Joint J. 2014 May;96-B(5):597-603.
2. Bachhal V, Jindal N, Saini G, Sament R, Kumar V, Chouhan D, Dhillon M. A new method of measuring acetabular cup antev-
ersion on simulated radiographs. Int Orthop. 2012;36:1813–1818.
3. Widmer KH A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty. 2004 Apr;19(3):387-90.
5. Murray DW: The definition and measurement of acetabular orientation. J Bone Joint Surg Br 1993 75:228,
6. Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220
7. Schwarz TJ et al. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study. Rofo. 2017 Sep;189(9):864-873.
Show More

最新版本4.5更新日誌

Last updated on 2022年11月10日
歷史版本
update for iOS 16.1 minor bugs fixed
Show More
Version History
4.5
2022年11月10日
update for iOS 16.1 minor bugs fixed
4.0
2022年04月23日
updated for 14.5 bugs fixed.
3.5
2020年02月22日
bugs fixed, calculation are now more precise, exclusively for radiologic anterversion and Inclination of cup.
3.0
2019年12月31日
-Pelvic tilt may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. We added mathematical correction to reduce these errors. The angle APP is added and in calculation and can be adjusted manually according to surgeons preference.
-RI-Radiographic Inclination and RA-Radiographic Anteversion values are adjusted by taking into account the Pelvic Tilt (APP angle ) according to mathematical correction algorithm.
-Operative Inclination (OI), Operative Anteversion (OA), Anatomical Inclination (AI), Anatomical Anteversion (AA) are calculated (Murray definition).
- RI or RA values are printed in red or green, according to measured value in cases these are in certain range (Lewinnek at al), indicating if the positioning of the cup is optimal (green) or not (red).


1.5
2019年09月29日
update for iOS 13 optimized for Dark Mode
1.0
2019年01月13日

CupAnteversionInclinationApp FAQ

點擊此處瞭解如何在受限國家或地區下載CupAnteversionInclinationApp。
以下為CupAnteversionInclinationApp的最低配置要求。
iPhone
須使用 iOS 16.1 或以上版本。
iPad
須使用 iPadOS 16.1 或以上版本。
Mac
須使用 macOS 12.3 或以上版本。
CupAnteversionInclinationApp支持英文

相關視頻

Latest introduction video of CupAnteversionInclinationApp on iPhone
Latest introduction video of CupAnteversionInclinationApp on iPhone
Latest introduction video of CupAnteversionInclinationApp on iPhone

CupAnteversionInclinationApp相關應用

你可能還喜歡

ORTHOPRACTIS.COM SINGLE MEMBER P.C. 開發者的更多應用