VictronConnect lets you get live status info and configure Victron products with built-in bluetooth support or using a VE.Direct Bluetooth LE dongle.

LIVE DATA:
Get instant data from your solar charger or battery monitor.

READ HISTORY RECORDS*:
Makes it easy to diagnose your installation.
With BlueSolar MPPT chargers you’ll get thirty days history records at one glance.

CONFIGURE SETTINGS:
Most exciting feature! Configure your device with just a few taps on your phone screen.
Simplifies all, navigate through the configuration pages, edit settings and changes will be sent instantly to your device.

UPDATE FIRMWARE:
Be always up to date. VictronConnect includes the latest firmware versions, when outdated firmware is detected you'll be prompted to update. It is also possible to update firmware manually.

DEMO MODE:
Select a product from the built-in demo library and discover all the features.

This app requires Bluetooth Low Energy, which is supported on the iPhone 4S and up, iPad Air and iPad Mini (3rd and 4th generation).

Supported Victron products:

* BMV 70x Battery Monitors

* BlueSolar & SmartSolar MPPT Chargers**

* VE.Direct Phoenix Inverters

* Blue Smart IP22 Chargers

* Blue Smart IP65 Chargers

* Blue Smart IP67 Chargers

* Peak Power Pack

* MultiPlus and Quattro with VE.Bus Bluetooth Smart Dongle

----
* Only on products with history support
** BlueSolar 70/15 excluded
VictronConnect 6.03 Update
2024-03-18
Minor bug fixes
More Information
Price:
Free
Version:
6.03
Size:
102.9 MB
Update Date:
2024-03-18
Developer:
Victron Energy

Safe to Download

AppPure.com and the download link of this app are 100% safe. The download link of this app will be redirected to the official App Store site, thus the app is original and has not been modified in any way.

Got it
X
Share

Share this page with your friends if you find it useful

Facebook Linkedin Pinterest Tumblr Twitter Whatsapp Line
6.03 2024-03-18
Minor bug fixes
5.99 2023-11-14
- Fix battery monitors first use setup
5.97 2023-10-04
- Add BMV-712 and SmartShunt Bluetooth firmware v2.46
5.96 2023-09-25
- Add VE.Bus Smart Dongle firmware v1.17
- Fix .bup firmware updates on iOS 17
- Fix some MPPT the settings save/load buttons
- Add new Multi models
- Make system configuration available in Inverter/Multi RS demo products
5.95 2023-08-31
- Various small fixes
5.93 2023-08-25
- Add new MultiPlus models
- Multi/Inverter RS: Allow "0" as minimum number of inverters to start on three phase systems
- Fix issues on some iPad Pro models
- Fix remove button in firmware list for user added files
- Multi RS: Hide single phase option on system configuration page. This is not supported yet.
- Add a button to show Instant Readout Bluetooth advertisement data key
5.92 2023-08-09
- Add VE.Bus Smart dongle firmware v1.16
- Add support for “Solar and wind priority” control

- Add Smart BMS firmware v1.09

- Add firmware v3.14 for SmartSolar 250/100 rev2 model
- Improve instructions/ease of use around the PV short relay reset mechanism
5.91 2023-06-05
- Add Inverter RS firmware v1.12: Add support for AC output parallel and 3-phase operation.
- Add Multi RS firmware v1.12
- Add VE.Bus Smart Dongle firmware v1.14
- Add a feature to lock VictronConnect on to a demo product. Useful for exhibitions and training.
- Various small fixes
5.90 2023-05-02
* Improve stored trends time-stamp accuracy of data stored before a reboot
* Improve service log mechanism to include more useful data in service reports
* VC-R: Fix a bug that makes VE.Bus Inverter/Chargers to be listed when the GX product is running Venus v3.0. These products are not supported by VC-R.
* Fix settings with radio buttons can report a wrong value after when pressing the cancel button. This issue didn’t affect the actual value of the setting.

Multi RS:
* Instant readout now notifies warnings, alarms and errors.
* Improve and add extra information to ESS mode selection
* Add new ESS modes (only for beta FW)
* Hide “Monitor PE to Neutral voltage” setting for models not supporting it
* Add new aux input modes
* Trends: Fix AC out power does not report data

VE.Bus Smart Dongle:
* Fix default PIN code warning when dongle is connected to a Multi/Quattro
* Fix VE.Bus settings load and restore for the “DC input low pre-alarm” setting:
* In case the DC input low-shutdown value was modified the “DC input low pre-alarm” could contain the wrong value.

Smart Battery Protect:
* Add firmware v2.11:
* Added support for Instant Readout
* VictronConnect can now show the most relevant Smart BatteryProtect data in the product list page without having to stablish a connection
* Improved “Disabled SBP will now try to pull output to 0V” behavior (introduced in v2.06)
* To prevent possible mosfet failures

SmartBMS & SmartBMS CL:
* Add firmware v1.08:
* Added support for Instant Readout
* VictronConnect can now show the most relevant Smart BMS data in the product list page without having to stablish a connection
* Removed BMS cable error detection
* Detection has been removed because it is impossible to detect a faulty BMS cable when there is more than one battery connected.
* Made sure that allow charge/discharge outputs (&LEDs) stay active at end of FW update
* Several internal improvements
* Smart BMS 12-200 only:
* Added Alternator-Only as remote-off option making it possible, to disable only Alternator when Remote OFF.
* Disabling both Alternator and System+ port can still be selected as remote-off option.
* Made sure that System+ charging stops when reaching Battery Charge Limit. As also the case for Alternator charging

EVCS:
* Add demo products

VE.Direct Smart Dongle, SmartSolar & SmartInverter:
* Add Bluetooth firmware v2.44:
* Fix VE.Smart networking and custom name not being cleared when “Restore default” for product is executed. Now, the only things not cleared by a restore default, on purpose, are Bluetooth pincode and bluetooth bonding.
* Fix: erratic values in battery temperature trend data (only applicable for SmartSolar).
* Fix: short interruption in the battery temperature trend data when charging stops (only applicable for SmartSolar).
* Some small VE.Smart Networking improvements

SmartLithium:
* Add firmware v1.31:
* Add support for hardware revision 2

Solar Chargers:
* Fix wrong error #26 description
5.83 2023-04-05
- Add Ukrainian translation
- Add SmartShunt firmware v4.14
- Add BMV-712 firmware v4.13
- Add Orion Smart firmware v1.13
5.82 2023-02-15
RS products:
- Add RS firmware v1.11

Multi RS:
- Fix AC input current scaling

VE.Bus Inverter/Charger:
- Add firmware v502

EVCS:
- Improve notifications related to not-configured modes
- Make possible to disable WiFi network scanning
- Fix misbehaviour of notifications panel

Battery monitor:
- Keep SOC on reset: Move "Keep SOC" to the top of options list
- Add BMV-712 rev2 to settings definitions. Enables save/load settings files.
- Add retained soc capability to BMV & SmartShunt demos
5.77 2022-11-02
- Add firmware v499 for Quattro 48/10000/140-2×100 & Quattro 48/8000/110-2×100
- MultiRS: Fix inconsistency on how frequency is shown for AC Out 2
- Remove RX port function settings in demo products of models that doesn't support them.
5.76 2022-10-25
- Fix various demo products
5.75 2022-10-14
Fix Cerbo-S GX is recognised as a different product
5.74 2022-09-26
- Fix in range products serial numbers are shown as "undefined" in VE.Smart networking config page.
- Improve internal products database
- Notify when there is a firmware update available for the Bluetooth interfaces
- Fix fetching trends data on reconnect
- Enable PIN code reset via PUK to all internal dongles
- Rename "broadcast data" to "instant readout"

MPPT Solar Chargers:
- Require confirmation when user changes the battery voltage
- Make sure to exit from voltage auto detection when user selects battery voltage
- Fix history CSV export can fail in certain situations

SmartSolar, BMV & SmartShunt:
- Set Bluetooth firmware v2.41 as optional update

Phoenix Inverter:
- Fix load widget shows "0" instead of load state

VE.Bust Smart Dongle:
- Fix connected Multi/Quattro is not added to "My devices"

Orion Smart:
- Reword "Charger enabled" to "Output enabled"

SUN Inverter:
- Enable settings file export/import
- Fix "Low battery shut down" and "Low battery restart & alarm" settings
- Fix history CSV export
5.73 2022-08-18
- Remove tail current maximum value limitation as it is not high enough for big batteries banks. Now the user can set any value and the product will clip it to boundaries if necessary. Applies to BlueSolar, SmartSolar, Multi/Inverter/MPPT RS, Smart Lynx BMS and SUN Inverter.
- Always show the broadcast data expand button, this allows to toggle the description text when all the data fits in one line.

GX products:
- Fix the GX device is not added to "My devices" when using Bluetooth.

VE.Direct Smart dongle:
- Add firmware v2.41: (update mandatory upon connection)
- Add Bluetooth live data advertisement support

Lynx Smart BMS:
- Add a disable/enable switch to the discharge floor setting.
- Add description for the discharge floor setting
- Add description for the batteries in parallel setting
- Reword battery capacity/voltage to Battery bank capacity/voltage.

Orion Smart:
- Add firmware v1.10: (optional update)
- Fix charge state report when charger is limited by the input voltage right after starting up. This caused the charger to report as being disabled in the VictronConnect app, even if it was already charging the battery. This bug was harmless for the charger, battery, or loads, only the report was wrong.

BMV & SmartShunt:
- Show the first use setup only when charged voltage has not been configured previously. This avoids the charged voltage to be silently changed when the first use setup is completed.

SmartSolar, BMV & SmartShunt:
- Mark Bluetooth firmware v2.41 as mandatory update
5.72 2022-07-25
- (New feature) Stored trends feature: BMV-712, SmartShunt, SmartSolar and Smart Battery Sense now store the trends data internally so trends data will remain after disconnecting.
- (New feature) Own products: Devices list is sorted by name and your products are kept at the top of the list.
- (New feature) Broadcast data: Known products immediately show the most important values in the devices list.
- Enable VictronConnect-remote for some VE.Can products. This feature requires Venus OS v2.90.
- Various firmware updates.
- Several internal improvements.
5.71 2022-07-19
- (New feature) Stored trends feature: BMV-712, SmartShunt, SmartSolar and Smart Battery Sense now store the trends data internally so trends data will remain after disconnecting.
- (New feature) Own products: Devices list is sorted by name and your products are kept at the top of the list.
- (New feature) Broadcast data: Known products immediately show the most important values in the devices list.
- Enable VictronConnect-remote for some VE.Can products. This feature requires Venus OS v2.90.
- Various firmware updates.
- Several internal improvements.
5.61 2022-07-01
- Add Smart Phoenix Inverter 48V 5000VA firmware v1.33
5.59 2022-04-04
- Add MPPT RS firmware v1.09
- Add Multi RS firmware v1.09
- Add Inverter RS firmware v1.09
- Fix battery monitor shows "nanm" as remaining time
- Remove the option for disabling float on Orion Smart.
5.58 2022-03-16
- Add Phoenix Inverter firmware update v1.30 for 48V 250VA models
- Fix batteries preset temperature compensation setting always displayed in Celsius although Fahrenheit is selected
- Fix MPPT RS 450/200 current limit setting
- Add new VE.Bus Inverter/Charger models
5.57 2022-03-04
- Minor fixes and additions

VE.Bus Inverter/Chargers:
- Add new models

SmartLithium:
- Fix input value range for the temperature offset setting is not valid when using Fahrenheit.
5.56 2022-02-09
- Add Inverter RS firmware v1.08
- Add MPPT RS firmware v1.08
- Add Multi RS firmware v1.08
- Add Lynx Smart BMS firmware v1.04
- Small fixes
5.54 2022-01-31
- Support new GX models
5.52 2022-01-03
Fix "Unknown error" is wrongly displayed in the live data page
Add AC input to Multi RS overview page
Add Smart Battery Sense firmware v1.10
Add SmartSolar, BMV-712 & SmartShunt Bluetooth firmware v2.37
5.48 2021-10-07
* Fix crashes when a GX device on local lan is detected multiple times. This can happen when a GX device is connected to LAN via ethernet and Wi-Fi simultaniously.

VE.Can MPPT Solar Chargers:
* Add firmware v3.07: (optional update)

MPPT Solar Chargers:
* Add firmware v1.59: (optional update)
* Fix some demo models

MPPT RS:
* Add firmware v1.05: (optional update)
* Add DC input resistance readout
* Rename imput mode from BMS to 2-Wire BMS
* Improve how the remote mode is handled and the use of BMS is adviced when a Lithium preset is selected.

Inverter RS:
* Add firmware v1.05: (optional update)
* Add DC ripple voltage readout

BMV-712 & SmartShunt:
* Add firmware v4.08 (optional update)
* For non-bmv monitor modes the current and power are inverted to match installation and visual feedback.
* Water Heater is added as a (load) option for Monitor Mode.

Blue Smart Chargers:
* Add firmware v3.42 for Blue Smart IP22 Chargers REV2 (optional update)

MPPT Control:
* Add firmware v1.03 (mandatory update upon connection)
5.47 2021-08-14
MPPT Solar Chargers:
- Fix temperature cut-off keeps showing as enabled after toggling the disable switch.
5.35 2020-11-04
- Improve VRM connection by retrying to connect before showing a timeout error.
- Fix VRM sign in button doesn't open the browser on iOS 14 when Safari is not the default browser. This issue also affects other links in VictronConnect.
- Add support for future products

MPPT Solar Chargers:
- Add firmware v1.54:
- Fix load output briefly turning off when charger is enters low power mode, introduced on v1.52 on SmartSolars.
- Improve error 38 detection for SmartSolars 250/60 and 250/70 models.

Smart Chargers:
- Fix CSV export: starting at second, column values are shifted left by one column.

Smart Battery Protect:
- Fix sometimes error/alarms notifications are not cleared

BMS-CL:
- Fix sometimes error/alarms notifications are not cleared
5.34 2020-10-22
- Sort VRM installations by name
- Add timeout when connecting to a Bluetooth product to prevent connection getting stuck and ensure that the retry mechanism is triggered.

Phoenix Smart Charger:
- Add firmware v3.31 update:
- Add support for VE.Smart networking
- Add history of the last 40 charge cycles, similar as the Blue Smart Chargers
- Use re-bulk voltage offset instead of absolute re-bulk voltage
- Improved temperature compensation
- Lower the minimum configurable charger current from 25% to 10% * Inominal
- Add low battery temperature cut-off: stop charging lithium batteries below 5°C (default)
- Requires VE.Smart networking temperature sensor, e.g. Smart Battery Sense
- Add tail current functionality
- When the charge current is below the threshold for 1 minute, the absorption stage is ended and the charger will switch to float/storage.
- Add high battery temperature condition to programmable relay
- Requires temperature sensor, e.g. Smart Battery Sense
- Allow 0% recondition current
- Setting it to 0% skips the recondition stage, if enabled
- Add Keep Alive support
- This improves Bluetooth connectability, with VictronConnect
- Add support for settings changed
- Add remark about voltages when charger has multiple outputs


Solar Chargers:
- Add firmware v1.53 update:
- Remove improvement, added on v1.52, of the remote voltage sense compensation to speed up filtering. That improvement is postponed for now.
- Fix bugs that caused the MPPT Control to get stuck on “CONNECTING” as well as “FETCHING HISTORY”.
- Includes changes in firmware v1.52:
- Include low power mode for the small models. Idle current consumption (when PV is around 0V) is reduced by around 70%.
- Improve remote voltage sense compensation to speed up filtering when necessary and improve voltage control response.
- Change 100/20 48V default battery changed from 48V to auto detection.
- Fix remote voltage compensation for small models. The voltage compensation of small MPPTs did not consider some current depended voltage drops, causing the MPPT to have a higher voltage setpoint, up to 200mV, depending on the MPPT current. This FW version fix that.

- Add firmware v3.02 for VE.Can and *.xup based firmware MPPT models:
- Fix bugs that caused the MPPT Control to get stuck on “CONNECTING” as well as “FETCHING HISTORY”. The changes are (a) that text messages are now always sent every 2 seconds and no longer interrupted when a hex message is received; and (b) the History total data is now always announced together with the history day0 data.
- Fix bug that resulted in the MPPT Control always showing the history of the moment that the MPPT Control was first connected to the MPPT. (Fix announce of day 0 history data)
- Includes changes firmware v3.01:
- Change firmware version number to v3.xx range to avoid confusion between different solar charger models.
- Improve error 28 trigger conditions.
- Improve detection of error 38/39 for 250V models.

VE.Smart Bluetooth Dongle:
- Add firmware v2.26 update
- Prevent switching to unsupported baud rates
- Support keep alive mechanism
- Fix to prevent fragmented responses which could cause failing update over BLE of attached product

MPPT Control:
- Add support for firmware updates
- Add firmware v1.02 update (mandatory):
- Solves MPPT Control getting stuck in "FETCHING HISTORY". We recommend to update the solar charger first; and then only update MPPT Control in case its still having issues.
- Makes the communication more robust

MPPT RS:
- Add display settings menu
- Include temperature unit setting

Inverter RS:
- Add display settings menu
- Include temperature unit setting

VE.Bus inverter/chargers:
- Fix L3 power output shows the value of L2 output
5.33 2020-09-30
- Add Orion Smart firmware v1.06 update: Bug fix regarding the possibility of having a misconfiguration on the engine shutdown detection settings causing the strategy to stop working (engine always considered to be shutdown).
5.32 2020-09-23
* Fix "Fetching data" message is shown on the background when the alert notification drawer is open.
* Fix connection process gets stuck at 20% when the bonding information is not valid, e.g., after changing the PIN code from a different phone.
* Fix default PIN code warning "Do not warn me again for this product" option sometimes is not applied until the app is restarted.
* Improve behavior when a scan is started before the previously product was actually disconnected
* Changes to Trends UI and zoom functionality
* Show short note when firmware library is empty
* Fix Lithium Iron Phosphate (LiFePo4) preset for non-MPPT products with equalization auto stop mode setting support.

Orion Smart:
* Add firmware v1.05:
* Add engine shutdown detection delay settings

Phoenix Smart Charger:
* Add remark "History data is for the total of all outputs" to history page (history is only available in beta firmware)
* Improve charge current setting adding minimum, low, and max current presets. Low current preset matches the charger low current mode so the charger LEDs behavior is the same than when enabling by pressing the physical button.


Solar Chargers:
* Add support for future MPPT models ()

Smart Chargers:
* Add support for VE.Smart networking (only supported by beta firmware)
* Layout fixes and improvements
* Fix reported power supply state
* Fix absorption time description
* Change the way the adaptive absorption time is displayed, make it similar to the MPPT for more consistency.
* Enabled more battery preset capabilities
* Improve re-bulk voltage offset setting
* Add "Why is the charger off?" functionality
* Add low temperature cut-off settings
* Add IMPULSE-II Smart IP65 firmware v3.17
* Add Blue Smart IP65 Charger 12/5 firmware v3.22 update
5.31 2020-09-01
- Fix connection gets stuck showing "Fetching data" when connecting to a Bluetooth dongle in fault state

BMV & SmartShunt:
- Fix issue setting battery capacity to a value greater than 999Ah
- Fix missing decimals for mid-point voltage alarm and relay

Smart Phoenix Inverter:
- Fix disable Bluetooth function
5.29 2020-08-05
- Fix BlueSolar VE.Can MPPT firmware update via VE.Direct Smart Dongle
5.27 2020-07-06
SmartLithium:
* Add firmware v1.19 update (mandatory)
* Fix issue with 12V batteries where cell 2 and cell 3 had a lower voltage when the battery was not charged for some time. (12V battery model only)
* Fine-tuned balancer behaviour

* Improve the warning and information messages in the firmware update page
* Improve troubleshooting information
* Show default PIN code to the connection progress pop-up
* Only advice to remove the product from the Bluetooth paired devices list when that could be the issue.
* Disconnect every Bluetooth product before starting a new scan. This prevents the state where a product could remain connected after an interrupted firmware update.
* Increase the number of lines logged into the service report.
5.26 2020-06-19
* Fix freezes for a small amount of time while retrieving installations from the VRM server
* Fix possible crashes after re-scan
* Fix devices in range list doesn't refresh when joining an existing VE.Smart network
* Fix settings save/load buttons sometimes remain disabled having to reconnect to activate them
* Fix the PIN dialog keeps the input of the first PIN change when changing the PIN twice on same session
* Remove duplicated demo products
* Do not show the default PIN code warning if there is a mandatory firmware update available
* Improve PIN code reset via PUK error handling


MPPT Solar Chargers:
* New "charger off reason" feature: Display the actual off reason reported by the charger and offers guidance for troubleshooting possible installation problems. This feature is not available for the following solar charger models:
* BlueSolar 70/15
* BlueSolar 75/10
* BlueSolar 75/15
* BlueSolar 100/15
* BlueSolar 100/30 rev1
* BlueSolar 150/35 rev1
* BlueSolar 75/50
* BlueSolar 100/50 rev1
* Disable equalization voltage setting when Lithium preset is selected
* Rename "ESS" state by "External control"

SmartLihium:
* Improve battery status reporting and remove the "Busy" state.

Orion Smart:
* Fix battery preset setting shows "Factory default" instead the name of the selected preset

InverterRS:
* Fix history CSV export
* Add SOC and temperature to the demo product

Smart Chargers:
* Fix wrong voltage limits on demos
5.25 2020-05-25
- Mark the VE.Direct Smart Dongle (Rev1) firmware v2.23 as a mandatory update. When a dongle running firmware v2.10 is connected to a BMV-70x the battery reading current is read only once and doesn't update when the value changes.

MPPT Solar Chargers:
- Fix an issue that can make the battery voltage settings don't show the 36&48V options when the MPPT actually supports them
5.24 2020-05-23
MPPT Solar Chargers:
* Fix a bug that makes battery current readout stop updating
* Fix Re-bulk offset setting shows the offset instead the resultant voltage when modifying it. This issue is only present German translation.

Smart Chargers:
* Fix main widget misalignment when in PSU mode and translation text is too long
5.23 2020-05-22
- Fix history CSV export
- Fix Orion Smart demos
- Fix updater issues when the update button is pressed while the connection is not ready.
5.22 2020-05-19
* Performance improvements
* Fix battery presets edition

VRM:
* Fix error "-100" on poor network connections or Venus devices with high CPU loads, now connection is retried and the error is better handled.

InverterRS:
* Add battery soc readout and battery monitor settings
* Add new overview page with current flow lines

VE.Bus Inverter/Chargers:
* Hide temperature compensation setting when Lithium battery setting is enabled
* Add firmware v473
* Added grid code for Denmark.
(based on “Technical regulation 3-3-1 for electrical energy storage facilities”)
* Added option to limit AC current to/from inverter for the grid codes:
Europe, Belgium, Austria and Germany.
* Added Lock-in/Lock-out on AC input voltage for the Cosϕ function for the grid codes:
Europe, Belgium and Austria

Phoenix Smart Charger:
* Add firmware update v3.19:
* Disable 30 seconds Bluetooth recovery time at power-up
* Bluetooth can be re-enabled through VE.Direct or by pressing the MODE button for 10s
* Hide re-bulk current setting; not used, but could still be set

BMV & SmartShunt:
* Increase displayed battery current resolution

Blue Smart Chargers:
* Add firmware v3.21 update:
* **Added custom battery settings**
* Added charge cycle history
* Keeps track of the last 40 charge cycles
* Keeps track of the cumulative data, like operating time, charged Ah, etc.
* Improved Bluetooth connectability
* Show charger as not-connectable (greyed out) in VictronConnect, when it is already connected to another device
* Extend bluetooth range for Blue Smart IP67 chargers
* Improved bluetooth stability when performing a firmware update
* Changed re-bulk strategy
* The charger now automatically jumps back to bulk from (almost) all states if the current demand exceeds the maximum charge current. Previously this was only possible from the float and storage state.
* A setting is introduced to set a current threshold for jumping back to bulk (default disabled). When the charge current in float or storage exceeds this threshold value it will jump back to bulk.
* Improved relay clicking when mains is disconnected

Solar Chargers:
* Add Bluetooth firmware v2.25
* Add firmware v1.49
* Improve PV Short Protection detection for 250V models when on ESS
* Add timeout to join a synchronised charging network
* Remove error 68. Now, the error will be no longer triggered when the same information comes from BLE and VE.Direct. A decision method based on priority is applied, where VE.Direct has a higher priority when compared to BLE. For more information, see MPPT Error Codes.
* Fix spurious charge algorithm reset after overshoot/zero current event.
* Add firmware v1.06 (VE.Can models)
* Update error 68 trigger conditions. Now, the error will be no longer triggered when the same information comes from BLE and VE.Direct/VE.Can. A decision method based on priority is applied, where VE.Direct/VE.Can have a higher priority when compared to BLE. Error will still be triggered if same data is received from VE.Direct and VE.Can. For more information, see MPPT Error Codes.
* Improved error 38/39 detection when charger is externally controlled (i.e. ESS mode).
* Fixed issue that could lead the MPPT to trigger error 67 (BMS missing) even when the BMS was present at the network. Also, the error could not be cleared properly.
* Change error 67 behavior by turning it into a warning, not error. Output voltage drops to the battery base voltage.
* Fix the reception of the charge current limit. That was a combined issue with Venus OS. The fix for the Venus is available on Venus OS v2.53 or higher.
* Fix NMEA device instance change when done over complex commands on VE.Can.
* Show PV power of all the synchronised charging MPPT's in the VE.Smart network

Peak Power Pack:
* Fix live data sometimes shows 0V when battery is fully charged
5.21 2020-05-18
* Performance improvements
* Fix battery presets edition

VRM:
* Fix error "-100" on poor network connections or Venus devices with high CPU loads, now connection is retried and the error is better handled.

InverterRS:
* Add battery soc readout and battery monitor settings
* Add new overview page with current flow lines

VE.Bus Inverter/Chargers:
* Hide temperature compensation setting when Lithium battery setting is enabled
* Add firmware v473
* Added grid code for Denmark.
(based on “Technical regulation 3-3-1 for electrical energy storage facilities”)
* Added option to limit AC current to/from inverter for the grid codes:
Europe, Belgium, Austria and Germany.
* Added Lock-in/Lock-out on AC input voltage for the Cosϕ function for the grid codes:
Europe, Belgium and Austria

Phoenix Smart Charger:
* Add firmware update v3.19:
* Disable 30 seconds Bluetooth recovery time at power-up
* Bluetooth can be re-enabled through VE.Direct or by pressing the MODE button for 10s
* Hide re-bulk current setting; not used, but could still be set

BMV & SmartShunt:
* Increase displayed battery current resolution

Blue Smart Chargers:
* Add firmware v3.21 update:
* **Added custom battery settings**
* Added charge cycle history
* Keeps track of the last 40 charge cycles
* Keeps track of the cumulative data, like operating time, charged Ah, etc.
* Improved Bluetooth connectability
* Show charger as not-connectable (greyed out) in VictronConnect, when it is already connected to another device
* Extend bluetooth range for Blue Smart IP67 chargers
* Improved bluetooth stability when performing a firmware update
* Changed re-bulk strategy
* The charger now automatically jumps back to bulk from (almost) all states if the current demand exceeds the maximum charge current. Previously this was only possible from the float and storage state.
* A setting is introduced to set a current threshold for jumping back to bulk (default disabled). When the charge current in float or storage exceeds this threshold value it will jump back to bulk.
* Improved relay clicking when mains is disconnected

Solar Chargers:
* Add Bluetooth firmware v2.25
* Add firmware v1.49
* Improve PV Short Protection detection for 250V models when on ESS
* Add timeout to join a synchronised charging network
* Remove error 68. Now, the error will be no longer triggered when the same information comes from BLE and VE.Direct. A decision method based on priority is applied, where VE.Direct has a higher priority when compared to BLE. For more information, see MPPT Error Codes.
* Fix spurious charge algorithm reset after overshoot/zero current event.
* Add firmware v1.06 (VE.Can models)
* Update error 68 trigger conditions. Now, the error will be no longer triggered when the same information comes from BLE and VE.Direct/VE.Can. A decision method based on priority is applied, where VE.Direct/VE.Can have a higher priority when compared to BLE. Error will still be triggered if same data is received from VE.Direct and VE.Can. For more information, see MPPT Error Codes.
* Improved error 38/39 detection when charger is externally controlled (i.e. ESS mode).
* Fixed issue that could lead the MPPT to trigger error 67 (BMS missing) even when the BMS was present at the network. Also, the error could not be cleared properly.
* Change error 67 behavior by turning it into a warning, not error. Output voltage drops to the battery base voltage.
* Fix the reception of the charge current limit. That was a combined issue with Venus OS. The fix for the Venus is available on Venus OS v2.53 or higher.
* Fix NMEA device instance change when done over complex commands on VE.Can.
* Show PV power of all the synchronised charging MPPT's in the VE.Smart network

Peak Power Pack:
* Fix live data sometimes shows 0V when battery is fully charged
5.19 2020-02-20
- Fix issues when pressing continue button after a firmware update is completed
5.18 2020-02-14
* Performance improvements
* Fix notifications drawer don't update the alarm/warning/error description is some cases
* Order demo groups alphabetically

SmartSolar VE.Can:
* Fix firmware updating via Bluetooth

GX devices:
* Improve Venus network settings layout
* Add new icons for Cerbo GX, Maxi GX, Octo GX and MultiPlus-II GX

Solar Chargers:
* Change default CSV name to SolarCharger instead of BlueSolar

Smart Chargers:
* Add default value to re-bulk current setting to the demo of those models that support advanced settings

Smart Battery Protect:
* Fix load output switch stays at off position when it should be in on position after pressing cancel in the deactivation warning dialog

BMV:
* Fix Input section is overlapped on BMV demos

SmartShunt:
* Add SmartShunt demo products

SmartLithium:
* Add 12V 100&150 Ah models
5.17 2020-02-04
* General performance improvements
* Do not show default PIN code warning when there is a mandatory update available
* Fix missing decimal digits and units for trends
* Show a warning when trying to use an invalid firmware file

GX devices:
* Auto select the correct host for the remote console when connected via Bluetooth

Solar Chargers:
* Improve StreetLight settings UX
* Improve TX port and Load output settings UX
* Add support for new models

Blue Smart Chargers:
* Do not show advanced settings on demos when not supported by the charger

Phoenix Inverter:
* Set 60Hz as default freq. for 120V Phoenix Inverter demos

BMV-720
* Optimise the firmware file format to improve the update speed
* No changes related, version is kept as v4.03.

Smart Chargers:
* Add re-bulk current setting
5.16 2019-12-20
- Small fixes
5.13 2019-10-29
- Various user interface fixes and improvements
- Fix firmware version is not shown in all the cases when the update is completed
- Fix “update succeeded” message is wrongly displayed when trying to update using an invalid file

VE.Smart network:
- Change the way that a VE.Smart network information is presented:
- Show devices that are in range for the connected product
- Devices in range signal strength

Smart Battery Sense:
- Add firmware update v1.05

Bluetooth internal and external dongles:
- Add Bluetooth firmware v2.23

MPPT SolarChargers:
- Add MPPT Solar Chargers firmware v1.46:
- Update marked mandatory only for SmartSolar as these models are affected by the bug described below.
- Fix bug on the internal temperature measurement that lead to not being able to de-rate the output current due to a high temperature nor triggering the over temperature protection. (Bug introduced on v1.30). This bug is only present in SmartSolar.
- Make 30 day history in demos more accurate

BMV-712:
- Add BMV-712 firmware v4.03:
- Fix an issue that makes the buzzer inaudible

Smart Battery Protect:
- Show the correct icon for Smart Battery Protect 48-100

SmartLithium:
- Add firmware version 1.17 update:
- Add cell under voltage pre-alarm threshold setting
- Add support for BMS Pre-Alarm
5.12 2019-10-28
- Fix firmware version is not shown in all the cases when the update is completed
- Fix “update succeeded” message is wrongly displayed when trying to update using an invalid file
- Various user interface fixes and improvements

VE.Smart network:
- Change the way that a VE.Smart network information is presented:
- Show devices that are in range for the connected product
- Devices in range signal strength

Smart Battery Sense:
- Add firmware update v1.05

Bluetooth internal and external dongles:
- Add Bluetooth firmware v2.23

MPPT SolarChargers:
- Add MPPT Solar Chargers firmware v1.46:
- Update marked mandatory only for SmartSolar as these models are affected by the bug described below.
- Fix bug on the internal temperature measurement that lead to not being able to de-rate the output current due to a high temperature nor triggering the over temperature protection. (Bug introduced on v1.30). This bug is only present in SmartSolar.
- Make 30 day history in demos more accurate

BMV-712:
- Add BMV-712 firmware v4.03:
- Fix an issue that makes the buzzer inaudible

Smart Battery Protect:
- Show the correct icon for Smart Battery Protect 48-100

SmartLithium:
- Add firmware version 1.17 update:
- Add cell under voltage pre-alarm threshold setting
- Add support for BMS Pre-Alarm
5.11 2019-09-18
Fix VictronConnect could not recover properly after an interrupted Bluetooth update of the Bluetooth microcontroller
5.8 2019-07-18
- Add support for Orion Smart
- Performance improvements
- Add instructional videos of how to remove the device pairing, required after a PIN code change

VE.Can MPPT:
- Include firmware v1.02
- Synchronized charging with VE.Can. This works the same as with previous models.
- Add ESS support.
- Add BMS support.

SmartSolar chargers, Smart BMV, Smart Phoenix Inverters & VE.Direct Smart Bluetooth dongle, Include firmware v2.19:
- Fix for using wrong BLE advertisement
- Fix for higher current consumption for Phoenix Inverter Smart in “Off” state.

Smart Battery Sense:
- Include firmware v1.04 update

Blue Smart Chargers:

- Update the link pointing to the manual shown when a firmware update fails

MPPT Solar Chargers:
- Demo products: Scale settings accordingly the battery voltage- Add instructional videos of how to remove the device pairing, required after a PIN code change
- Add support for Orion Smart
- Performance improvements

VE.Can MPPT:
- Include firmware v1.02
- Synchronized charging with VE.Can. This works the same as with previous models.
- Add ESS support.
- Add BMS support.

SmartSolar chargers, Smart BMV, Smart Phoenix Inverters & VE.Direct Smart Bluetooth dongle, Include firmware v2.19:
- Fix for using wrong BLE advertisement
- Fix for higher current consumption for Phoenix Inverter Smart in “Off” state.

Smart Battery Sense:
- Include firmware v1.04 update

Blue Smart Chargers:

- Update the link pointing to the manual shown when a firmware update fails

MPPT Solar Chargers:
- Demo products: Scale settings accordingly the battery voltage
5.7 2019-05-10
- Fix PIN code change button is not shown

MPPT Solar Chargers:
- Prepare support for future firmware versions
5.6 2019-05-08
- Fix firmware update retry is not triggered when reconnecting after an unsuccessful firmware upadte.
- Internal improvements
- Fix disable Bluetooth toggle is shown twice for some products
- Make trends use user selected temperature unit
- Fix typos in Dutch and German translations

GX devices:
- Show firmware version when the GX device is running firmware >= 2.30
5.5 2019-05-02
- Add support for Phoenix Smart Chargers.
- Add a setting to show temperature units in Fahrenheit.
- Add trend graphics for BMV, MPPT and Smart Battery Sense.
- Add onboarding, shows to the user a brief description of the available options.
- Add new features highlight on home screen.
- Add new features highlight on home screen.
- Improve reset pin code by PUK handling.
- Fix GX log converter day light saving issues.
- Fix EasySolar2 GX, Multiplus2 GX and Generic Venus devices are shown as Unknown devices when discovered over UPnP.
5.4 2019-03-08
Smart Lithium Batteries:
- Add firmware v1.16 update:
Fix temperature inaccuracies. After updating to this version you can wait for the automatic calibration to take place or go in and set the temperature offset immediately. When doing so; the automatic calibration will not take place.

Add Venus device discovery via UPnP:
- List and connect to all the Venus devices available on a local network, now the remote console and VRM portal access are just one click away.
- Easily set up your Venus GX; Connect to its built-in Wi-Fi access point and use VictronConnect to open the remote console and configure the device.
5.3 2019-02-10
- Fix English language is not selectable
- Improve Spanish translation

BMV Battery monitor:
- Fix "Battery starts synchronized" setting

Peak Power Pack:
- Fix wrong status is shown
- Add missing alarms
- Fix "0V" is displayed in case of an over voltage.

Smart Phoenix Inverter:
* Show the correct product icon for 1600/2000VA models

MPPT Solar Chargers:
- Include firmware v1.39 update:
- Reset-to-defaults: maintains battery voltage (12..48V) as long as the unit remains powered. Automatic voltage detection takes place on next power-cycle.
5.2 2019-01-09
- Fix page device page is not closed after reconnection timeout
- Fix PIN code can't be changed because the keyboard overlaps the “Accept” button

New products support:
- Smart Battery Protect
- Smart Phoenix Inverter

BMV Battery Monitor:
- BMV 712 Bluetooth firmware update v2.14

- BMV Battery monitor firmware v3.10(BMV 70x) and v4.01(Smart BMV) update
- Add “Battery starts synchronized” setting

VE.Direct Bluetooth Smart Dongle:
- Firmware v2.15 update:
- Increased VE.Smart transmission robustness.
- Start advertising after 20 seconds when no successful VE.Direct communication was possible

MPPT Solar Chargers:
- Add scrollbar to presets list
- Fix history totals text overlap
- SmartSolar Bluetooth firmware v2.14 update:
- Increased VE.Smart transmission robustness.
- Start advertising after 20 seconds when no successful VE.Direct communication was possible.

Smart Battery Sense:
- Add firmware v1.03 update
- Improve Bluetooth range

VE.Bus Inverter/Charger:
- Fix overload alarm icon is missing
5.1 2018-11-23
SmartLithium
* Include firmware v1.15 update
* Add "Allowed-To-Charge minimum temperature" setting
* By default it disables charge when battery temperature is below 5C.
* Fix SmartLithium disappears from de devices list after disconnecting.

BMV Battery monitor:
* Fix an issue that makes BMV disappear from devices list after disconnecting. This issue only affects to BMV which are configured for VE.Smart networking.

MPPT solar chargers:
* Fix AES time show undefined in the algorithm description

Phoenix Inverter:
* Fix AC output setting limits in demo products
5.0 2018-10-09
- Fix issue that can cause VictronConnect get stuck at 93% during a VE.Direct product firmware update

MPPT solar chargers:
- Added firmware v1.37 update
- Fix Automatic Energy Selector load output mode is not listed (only for SmartSolar)

BMV battery monitor:
- Fix time remaining displays “0m” when no current is flowing from or to the battery
4.9 2018-08-23
VE.Bus Smart Bluetooth Dongle
- Added firmware v1.07 update
- Fixed an issue that makes the page show no values in some situations
- Hide SOC items when battery monitor is disabled
- Added missing Multi's model names
- Fix issues when connected Multi/Quattro firmware version is lower than 415.
- Warn about minimum firmware version

MPPT solar chargers:
- Added firmware v1.36 update for 250V models
- Load output: User algorithm 1&2 minimum voltage is now 10V for 12V systems.

BMV battery monitor:
- Added power value reading to the main page
- Fix time to go reported as “Infinite” instead of “0h” when discharge floor SOC level is reached
- Fix high voltage relay setting reports wrong values when editting for a first time in the session

Blue Smart Charger:
- Show correct value for low current setting in demo products
4.8 2018-07-05
- Add support for VE.Bus Smart Dongle
- Add SmartLithium 24V 200Ah demo
- Fix device filtering needs to be set after each scan
4.7 2018-06-09
- Fix products settings page is empty after automatic reconnection.
- Improve iPhone X support

IP65 Blue Smart Charger:
- Fix test stage not being shown for Blue Smart IP65 chargers
4.6 2018-06-04
- Improve VE.Direct firmware update robustness

- Add firmware v1.33 update for 250V models
- Further improve PV Short protection.
- Fix in reporting current/wattage/state when the unit is not charging.

- Add Chinese translation
4.5 2018-04-26
- Fix French translation for “Switch on before sunrise” in Streetlight settings

Solar Chargers:
- Add firmware v1.32 update for 250V models
- Improve power-stage shutdown sequence.
- Improve / speed-up PV Short protection and introduce error code 39
- Fix PV current value stops updating two minutes after connecting
- Fix oldest day record is not exported to CSV file

BMV battery monitor:
- Fix temperature alarm and relay settings are always reported as disabled when Fahrenheit unit is selected
4.4 2018-03-16
Solar Chargers:
- Add VE.Smart Networking support
- Added firmware v1.30 update
- Added internal bluetooth firmware v2.12 update
- Add low temp cut-off setting, prevents damage in lithium batteries by disabling the charge during low temperature conditions.
- Show battery temperature when the MPPT is configured in a VE.Smart network where the battery temperature is available.
- Send local time to the MPPT to help streetlights functionality synchronization.
- Fix a bug that keeps streetlights on after sunrise.

BMV battery monitor:
- Added internal bluetooth firmware v2.12 update
- Added support for VE.Smart Networking
- Fix mid-point deviation unit, it was “V” when it should be “%”

SmartLithium:
- Added firmware v1.12 update
- Add “Allowed-To-Discharge cell voltage” setting
- Fix low cell voltage alarm

VE.Smart dongle:
- Added firmware v2.12 update (only for rev2 units)
- Added support for VE.Smart Networking

SmartBatterySense:
- Added firmware v1.02 update
- Added support for VE.Smart Networking (Voltage & Temp)

PeakPowerPack:
- Show confirmation dialog before switching to hibernate
4.3 2018-02-08
- Fix duplicated error message when loading an invalid settings file.
- Allow restoring settings from files created with previous VictronConnect versions

SmartLithium:
- Disable false low cell voltage alarm
- Rename battery to voltage in right panel

MPPT Solar chargers:
- Fix save/load settings functionality on BlueSolar 150/100 model
- Add relay state to live data page
- Add an error in one of the history records of the demo products
- Rename load output to virtual load output on devices without load output
- Add description to day/night detection settings
- History graphs:
- Hide Bluk, Absorption or Float segments when the state was not reached
- Improve bar length on days without production
- Fix daily records values are partially hidden on some small screens, for example iPhone 5 & iPhone SE
- Fix text overlapping due to translations

Phoenix Inverters:
- Add mode setting, mode now can be switched between on, off and ECO
- Add support for future models
- Add firmware v1.14 update for 800VA models

Blue Smart Chargers:
- Improve Bluk state description when Li-ion battery is selected
4.2 2018-01-09
- Completely redesigned user interface:
- Context help for settings
- Improved user experience
- Smoother navigation

- Added translations: Dutch, French, German, Italian and Spanish.

SmartLithium:
- New firmware update v1.07

MPPT solar chargers:
- Included firmware v1.29 update
4.0 2018-01-06
- Completely redesigned user interface:
- Context help for settings
- Improved user experience
- Smoother navigation

- Added translations: Dutch, French, German, Italian and Spanish.

SmartLithium:
- New firmware update v1.07

MPPT solar chargers:
- Included firmware v1.29 update
3.2 2017-08-14
BMV:
- Fix save/load settings buttons not displayed on BMV700

Settings:
- Add support for the new SmartSolar 75/10, 75/15, 100/15, 100/20, 100/30, 100/50, 150/35 & 150/100.

Demos:
- Add SmartSolar 75/10, 75/15, 100/15, 100/20, 100/30, 100/50, 150/35 & 150/100 to the demo library.

Blue Smart Chargers:
- Fix low current mode toggled when opening app from background.
- Show the proper firmware error messages when the update fails.
- Improve firmware update error message including a link to Victron Live troubleshooting.
- Include firmware v3.0 update:
- Internal improvements
- For some models the update might take a little longer (approx. 10-15 seconds).
3.1 2017-08-01
- Settings files: Save, load and share product settings.

- Demo products. A demo product can be used to:
- Learn and show the options available for different products.
- Create a specific setup, save that and send it to a customer so they can put it in their device.
- Besides loading products from the standard library, it is also possible to load it from a saved file.

- Allow filtering of the device list
- Feedback when a setting is correctly stored in the device
- General interface improvements

BlueSolar & SmartSolar MPPT chargers:
- Include firmware v1.27 update
- Added a button to disable the charger
- Added StreetLight night and day detection delay setting
- Added inverted load on/off mode for Rx port function
- Remove automatic battery voltage detection option:
- Added a button to manually start Equalisation. (note this is not available for older models)
3.0 2017-07-06
Add manual firmware updates for Bluetooth

SmartLithium batteries:
- Rename “Communication error” to “Internal communication failure”.
- Improve BMS state information display
- SmartLithium firmware v1.06 update:
- Fix a problem with internal communication
2.9 2017-06-13
SmartSolar 250/85 & SmartSolar 250/100 firmware v1.25 update
2.8 2017-05-16
MPPT Solar Chargers:
- Include firmware v1.24 update for Smart Solar 250/100 and 250/85
- Bug-fix in the battery voltage setting: the voltage always read as AUTO even if it is manually selected. Updating the MPPT 250/100 or 250/85 from v1.23 to v1.24 will change the voltage setting to 'AUTO', make sure to set the battery voltage to the correct voltage after updating.

Phoenix Inverters:
- Improve live data page
- Set minimum value for “ECO minimum wake-up power” setting to 15W.
2.7 2017-04-25
- MPPT chargers firmware v1.23 update
2.6 2017-04-20
- MPPT solar chargers firmware update
- Improve firmware update robustness
2.5 2017-04-18
- Add support for 120V VE.Direct Phoenix Inverters
- Add support for future new products
2.4 2017-03-24
VE.Direct Bluetooth Smart dongle:
- New firmware update 2.10
- Improved communications robustness
- Add support for new VE.Direct dongle

SmartSolar MPPT:
- Show the correct icon when updating firmware
- Fix battery voltage can't be set to 48V on some models
- New Bluetooth firmware update: v2.10

SmartLitihum batteries:
- New firmware update v1.05
- Fix cell numbering on live data page

Phoenix Inverter:
- Fix a typo in temperature alarms

Peak Power Pack:
- Rename “Mover” to “High current output(mover)” in live data page