Heating Pipe Size
Size heating & cooling pipes
$5.99
2.3for iPhone, iPad and more
Age Rating
Heating Pipe Size Screenshots
About Heating Pipe Size
Estimate required pipe diameter of a closed hydronic heating or cooling system in an instant and calculate pressure drop to determine required circulation pump characteristics (flow and head). Easy to use, quick and accurate results.
Enter the required heating or cooling output and water flow and return temperatures. Choose pipe material. The recommended pipe diameter is already there, presented as a standard DN.
Additionally, choose the recommended or a custom pipe diameter and specify pipe section length and fittings. Results include water flow rate, velocity, pressure drop and pressure drop per 100 m of straight pipe and can be used to determine the parameters of a circulation pump.
## Features:
- Simple to use;
- Suitable for hydronic (water-based) heating and cooling systems;
- Suitable for a large range of heating and cooling outputs;
- Predefined pipe materials;
- Water temperature range from 1 to 99 ºC;
- Completely independent from any manufacturers;
- No login needed, no data connection needed;
- No data collection;
- No subscriptions, one-time purchase only;
- Very quick calculation with no delays;
## Possible uses of the application:
- Quickly estimate required pipe diameter when designing a hydronic (water-based) closed heating or cooling system.
- Quickly determine circulation pump requirements (flow and head), whether it be a new system or a replacement pump.
## Notes:
- It is recommended to calculate every section of the piping system separately and additionally check the whole system pressure drop.
- The application is only useful for calculations of hydronic (water based) closed heating or cooling systems. Other systems and media are not supported.
- Only metric units are supported.
- The application, while accurate, is not meant as a complete replacement of specialized software for heating and cooling system design.
The application doesn't require data connection. It doesn't require and doesn't collect any personal data. It also doesn't contain third-party ads or code. Also: no in-app purchases, no subscriptions.
Enter the required heating or cooling output and water flow and return temperatures. Choose pipe material. The recommended pipe diameter is already there, presented as a standard DN.
Additionally, choose the recommended or a custom pipe diameter and specify pipe section length and fittings. Results include water flow rate, velocity, pressure drop and pressure drop per 100 m of straight pipe and can be used to determine the parameters of a circulation pump.
## Features:
- Simple to use;
- Suitable for hydronic (water-based) heating and cooling systems;
- Suitable for a large range of heating and cooling outputs;
- Predefined pipe materials;
- Water temperature range from 1 to 99 ºC;
- Completely independent from any manufacturers;
- No login needed, no data connection needed;
- No data collection;
- No subscriptions, one-time purchase only;
- Very quick calculation with no delays;
## Possible uses of the application:
- Quickly estimate required pipe diameter when designing a hydronic (water-based) closed heating or cooling system.
- Quickly determine circulation pump requirements (flow and head), whether it be a new system or a replacement pump.
## Notes:
- It is recommended to calculate every section of the piping system separately and additionally check the whole system pressure drop.
- The application is only useful for calculations of hydronic (water based) closed heating or cooling systems. Other systems and media are not supported.
- Only metric units are supported.
- The application, while accurate, is not meant as a complete replacement of specialized software for heating and cooling system design.
The application doesn't require data connection. It doesn't require and doesn't collect any personal data. It also doesn't contain third-party ads or code. Also: no in-app purchases, no subscriptions.
Show More
What's New in the Latest Version 2.3
Last updated on Nov 2, 2022
Old Versions
Corrected link in help.
Updated for newer OS versions.
Updated for newer OS versions.
Show More
Version History
2.3
Nov 2, 2022
Corrected link in help.
Updated for newer OS versions.
Updated for newer OS versions.
2.2
Apr 14, 2021
Small changes.
2.1
Jan 8, 2020
- New look.
- Dark Mode.
- Small updates.
- Dark Mode.
- Small updates.
2.0
Jun 14, 2019
General updates.
Support for newer devices.
Support for newer devices.
1.7
Jul 2, 2015
- German language;
- New design with emphasis on important results;
- Better formatting of numerical results;
- Notes on results;
- Ability to export results via email;
- New design with emphasis on important results;
- Better formatting of numerical results;
- Notes on results;
- Ability to export results via email;
1.6
Mar 13, 2015
- iPad support;
- All iPhone screen resolutions supported;
- Minor changes.
- All iPhone screen resolutions supported;
- Minor changes.
1.5
Oct 14, 2013
- redesigned for iOS 7;
- new icon;
- new icon;
1.1
Oct 4, 2012
- iPhone 5 screen support;
- Recommended pipe diameter displayed as a standard DN;
- Water velocity added to the displayed results;
- General improvements.
- Recommended pipe diameter displayed as a standard DN;
- Water velocity added to the displayed results;
- General improvements.
1.0
May 22, 2012
Heating Pipe Size FAQ
Heating Pipe Size is available in regions other than the following restricted countries:
Russia
Heating Pipe Size supports English, German
Click here to learn how to download Heating Pipe Size in restricted country or region.
Check the following list to see the minimum requirements of Heating Pipe Size.
iPhone
Requires iOS 15.0 or later.
iPad
Requires iPadOS 15.0 or later.
Mac
Requires macOS 12.0 or later.
iPod touch
Requires iOS 15.0 or later.