NPC LSI Calc

NPC LSI Calc



$4.99

1.2for iPhone, iPad and more
6.5
6 Ratings
National Plasters Council, Inc
Developer
15.8 MB
Size
Sep 3, 2021
Update Date
#33
in Business
4+
Age Rating
Age Rating
4+
Apps in this category do not contain restricted content.
9+
Apps in this category may contain mild or occasional cartoon, fantasy or real-life violence, as well as occasional or mild adult, sexually suggestive or horrifying content and may not be suitable for children under 9 years of age.
12+
Apps in this category may contain occasional mild indecent language, frequent or intense cartoon or real-life violence, minor or occasional adult or sexually suggestive material, and simulated gambling, and may be for children under 12 years of age.
17+
You must be at least 17 years old to access this App.
Apps in this category may contain frequent and intense offensive language; Frequent and intense cartoon, fantasy or realistic violence: frequent and intense adult, scary and sexually suggestive subjects: as well as sexual content, nudity, tobacco, alcohol and drugs, may not be suitable for children under 17 years of age.
NPC LSI Calc Screenshots
NPC LSI Calc poster
NPC LSI Calc posterNPC LSI Calc posterNPC LSI Calc posterNPC LSI Calc posterNPC LSI Calc poster

About NPC LSI Calc

The NPC LSI Calc is the newest, most advanced and most accurate calculator for determining the Langelier Saturation Index (LSI) for swimming pool and spa water. It was developed by noted pool and spa water chemistry expert and author, Robert W. Lowry. It is the only LSI calculator that currently has exact adjustments for cyanuric acid and borate.

The LSI is used to predict if pool or spa water is corrosive, balanced or scaling. The NPC LSI Calc uses the original mathematical equations which use logarithms, square roots, and interpolated constants for calculations. We do not use inaccurate lookup tables and factors. The actual water test results are used for calculations.

The NPC LSI Calc is easy to use, you input the customer or pool name and then the water test results for pH, Total Alkalinity (TA), Cyanuric Acid (CYA) Borate (B) Calcium Hardness (CH), Total Dissolved Solids (TDS), and the water Temperature (T) in degrees Fahrenheit. The LSI with adjustments is automatically calculated and displayed. The background color of the LSI value changes from green to amber to red depending on whether the water is Corrosive, Acceptable, Ideal, or Scaling. This gives a visual or at a glance notice of the water’s condition.

The original LSI was never intended for predicting corrosive, balanced or scaling water conditions for pools or spas. In fact, it was developed in 1936 which was many years before the development of Cyanuric Acid (CYA) which became popular around 1960 and remains so. The very popular trichlor chlorine tablets actually contain 56 % CYA and so as chlorine is dispensed, the CYA builds up in the water. CYA has a direct influence on Total Alkalinity (TA) so an adjustment had to be made to the original LSI calculation.

Another family of chemicals that have become popular recently as a pH buffer and algaestat in swimming pool and spa water are borates. Borates also have an influence of TA. Using borates in pool or spa water keeps the pH from rising but also requires an adjustment to TA and therefore has an effect on the LSI calculation too.

We have determined the exact affect borate and CYA will have on LSI calculations and built in the mathematical adjustments to the NPC LSI Calc App.

The goal mathematically is to have an LSI of near 0.00 but any value from –0.30 to + 0.50 is either Acceptable or Ideal. Positive values show increasing tendencies for forming scale and values more than +0.50 indicate scaling water conditions that require action. Negative values show increasing tendencies for being corrosive or aggressive and values greater than –0.30 indicate corrosive water that requires action.

We do not recommend which water conditions to change or chemical amounts to adjust the water balance or LSI. Which condition to adjust is best accomplished by the service tech, pool owner or pool store. There may be reasons that one condition or another cannot be changed or perhaps a condition is easier to change than another. But you can input new amounts for any condition to see what affect it will have on LSI.

Results can be saved and reviewed. The number of records saved is only limited by your phone’s memory. It is easy to delete of records.

Protecting the pool or spa surface, plumbing and equipment and having balanced water for your customers, your family or guests are easy with the NPC LSI Calc.
Show More

What's New in the Latest Version 1.2

Last updated on Sep 3, 2021
Old Versions
Issue Fixes
Added Carbonate Alkalinity calculations
Show More
Version History
1.2
Sep 3, 2021
Issue Fixes
Added Carbonate Alkalinity calculations
1.1
Oct 17, 2018
Bug Fixes & Improvements
1.0
Sep 4, 2017

NPC LSI Calc FAQ

Click here to learn how to download NPC LSI Calc in restricted country or region.
Check the following list to see the minimum requirements of NPC LSI Calc.
iPhone
Requires iOS 10.0 or later.
iPad
Requires iPadOS 10.0 or later.
iPod touch
Requires iOS 10.0 or later.
NPC LSI Calc supports English

NPC LSI Calc Alternative

You May Also Like