Climate tools

Climate tools



무료

4.1for iPhone, iPad and more
Carel Industries s.r.l.
Developer
9.7MB
Size
Nov 4, 2015
Update Date
Utilities
Category
4+
Age Rating
Age Rating
4+
Apps in this category do not contain restricted content.
9+
Apps in this category may contain mild or occasional cartoon, fantasy or real-life violence, as well as occasional or mild adult, sexually suggestive or horrifying content and may not be suitable for children under 9 years of age.
12+
Apps in this category may contain occasional mild indecent language, frequent or intense cartoon or real-life violence, minor or occasional adult or sexually suggestive material, and simulated gambling, and may be for children under 12 years of age.
17+
You must be at least 17 years old to access this App.
Apps in this category may contain frequent and intense offensive language; Frequent and intense cartoon, fantasy or realistic violence: frequent and intense adult, scary and sexually suggestive subjects: as well as sexual content, nudity, tobacco, alcohol and drugs, may not be suitable for children under 17 years of age.
Climate tools 스크린 샷
Climate tools 포스터Climate tools 포스터Climate tools 포스터Climate tools 포스터Climate tools 포스터
Climate tools 포스터Climate tools 포스터Climate tools 포스터Climate tools 포스터Climate tools 포스터

About Climate tools

The ultimate app for air psychometrics and evaporative cooling!
What are the air characteristics given the current values of temperature and humidity? How can I calculate the mix of two air stream? What is the humidification load for my AHU? These are some of the questions this app can provide answers for, and, on top, also estimates of power saved by evaporative cooling.

There are 9 functions available inside the app:

· AIR calculates the characteristic parameters of the air by entering 2 of the following 4 values: dry-bulb temperature (DBT), wet-bulb temperature (WBT), %rh, humidity ratio. The outputs are: dew-point temperature, specific enthalpy, density, specific volume, vapor pressure, vapor density

· MIX calculates the characteristics of the mixture from the properties of two air streams (DBT, WBT, %rh, W, flow rate)

· HUMIDIFICATION LOAD 1 calculates the humidification load based on an air current upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification) and the conditions of pre-heating

· HUMIDIFICATION LOAD MIX calculates the humidification load from the mixture of 2 air streams upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification), the conditions of pre-heating, the characteristics of the mixture of the two air streams upstream of the humidifier

· DEC (Direct Evaporative Cooling) calculates the cooling, as temperature and as power, of an air stream by the evaporation of water sprayed in it

· IEC (Indirect Evaporative Cooling) calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed in a secondary air stream that does NOT mix with the primary stream. The primary and secondary streams pass through a cross-flow heat exchanger

· DEC + IEC calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed both in the primary stream and in a secondary air stream. The primary and secondary streams pass through a cross-flow heat exchanger WITHOUT mixing. The secondary stream is the exhausted part of the return air. If the exhaust flow is less than the primary flow, the part of return air not exhausted is mixed with the cooled primary air after the heat exchanger.

· EVAPORATIVE COOLING calculates the additional heat rejected by a condenser coil/dry cooler when they are sprayed by water, assuming that water completely wets the exposed surface of the heat-rejection coil.

· AFTER THE AIR HUMIDIFIER IN AHU/DUCT calculates the conditions downstream of the humidifier in AHU/duct once the environment’s set point and internal sensible and latent loads are entered.
Show More

최신 버전 4.1의 새로운 기능

Last updated on Nov 4, 2015
오래된 버전
This app has been updated by Apple to display the Apple Watch app icon.

new ebooks request form
Show More
Version History
4.1
Nov 4, 2015
This app has been updated by Apple to display the Apple Watch app icon.

new ebooks request form
4.0
Sep 1, 2015
- Bug fixing.
- New Ebook Abstract from "Evaporative cooling".
- full ebook versions can be received upon request.
3.0
May 7, 2015
- abstract from "Air Humidification" book.
- the full ebook can be received upon request.
2.1
Sep 18, 2014
iPad version
minor bug fixing
2.0
Sep 3, 2014
new graphic interface and bug fixing
1.1
Jul 12, 2012
Bug fix
1.0
Apr 9, 2012

Climate tools FAQ

제한된 국가 또는 지역에서 Climate tools를 다운로드하는 방법을 알아보려면 여기를 클릭하십시오.
Climate tools의 최소 요구 사항을 보려면 다음 목록을 확인하십시오.
iPhone
iOS 7.1 이상 필요.
iPad
iPadOS 7.1 이상 필요.
iPod touch
iOS 7.1 이상 필요.
Climate tools은 다음 언어를 지원합니다. 영어, 이탈리아어

Climate tools 대안

당신은 또한 좋아할 수도 있습니다

Carel Industries s.r.l.에서 더 많은 것을 얻기