Climate tools

Climate tools



免費

4.1for iPhone, iPad and more
Carel Industries s.r.l.
Developer
9.7 MB
Size
2015年11月04日
Update Date
Utilities
Category
4+
Age Rating
Age Rating
4+
Apps in this category do not contain restricted content.
9+
Apps in this category may contain mild or occasional cartoon, fantasy or real-life violence, as well as occasional or mild adult, sexually suggestive or horrifying content and may not be suitable for children under 9 years of age.
12+
Apps in this category may contain occasional mild indecent language, frequent or intense cartoon or real-life violence, minor or occasional adult or sexually suggestive material, and simulated gambling, and may be for children under 12 years of age.
17+
You must be at least 17 years old to access this App.
Apps in this category may contain frequent and intense offensive language; Frequent and intense cartoon, fantasy or realistic violence: frequent and intense adult, scary and sexually suggestive subjects: as well as sexual content, nudity, tobacco, alcohol and drugs, may not be suitable for children under 17 years of age.
Climate tools 螢幕截圖
Climate tools 海報Climate tools 海報Climate tools 海報Climate tools 海報Climate tools 海報
Climate tools 海報Climate tools 海報Climate tools 海報Climate tools 海報Climate tools 海報

About Climate tools

The ultimate app for air psychometrics and evaporative cooling!
What are the air characteristics given the current values of temperature and humidity? How can I calculate the mix of two air stream? What is the humidification load for my AHU? These are some of the questions this app can provide answers for, and, on top, also estimates of power saved by evaporative cooling.

There are 9 functions available inside the app:

· AIR calculates the characteristic parameters of the air by entering 2 of the following 4 values: dry-bulb temperature (DBT), wet-bulb temperature (WBT), %rh, humidity ratio. The outputs are: dew-point temperature, specific enthalpy, density, specific volume, vapor pressure, vapor density

· MIX calculates the characteristics of the mixture from the properties of two air streams (DBT, WBT, %rh, W, flow rate)

· HUMIDIFICATION LOAD 1 calculates the humidification load based on an air current upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification) and the conditions of pre-heating

· HUMIDIFICATION LOAD MIX calculates the humidification load from the mixture of 2 air streams upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification), the conditions of pre-heating, the characteristics of the mixture of the two air streams upstream of the humidifier

· DEC (Direct Evaporative Cooling) calculates the cooling, as temperature and as power, of an air stream by the evaporation of water sprayed in it

· IEC (Indirect Evaporative Cooling) calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed in a secondary air stream that does NOT mix with the primary stream. The primary and secondary streams pass through a cross-flow heat exchanger

· DEC + IEC calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed both in the primary stream and in a secondary air stream. The primary and secondary streams pass through a cross-flow heat exchanger WITHOUT mixing. The secondary stream is the exhausted part of the return air. If the exhaust flow is less than the primary flow, the part of return air not exhausted is mixed with the cooled primary air after the heat exchanger.

· EVAPORATIVE COOLING calculates the additional heat rejected by a condenser coil/dry cooler when they are sprayed by water, assuming that water completely wets the exposed surface of the heat-rejection coil.

· AFTER THE AIR HUMIDIFIER IN AHU/DUCT calculates the conditions downstream of the humidifier in AHU/duct once the environment’s set point and internal sensible and latent loads are entered.
Show More

最新版本4.1更新日誌

Last updated on 2015年11月04日
歷史版本
This app has been updated by Apple to display the Apple Watch app icon.

new ebooks request form
Show More
Version History
4.1
2015年11月04日
This app has been updated by Apple to display the Apple Watch app icon.

new ebooks request form
4.0
2015年09月01日
- Bug fixing.
- New Ebook Abstract from "Evaporative cooling".
- full ebook versions can be received upon request.
3.0
2015年05月07日
- abstract from "Air Humidification" book.
- the full ebook can be received upon request.
2.1
2014年09月18日
iPad version
minor bug fixing
2.0
2014年09月03日
new graphic interface and bug fixing
1.1
2012年07月12日
Bug fix
1.0
2012年04月09日

Climate tools FAQ

點擊此處瞭解如何在受限國家或地區下載Climate tools。
以下為Climate tools的最低配置要求。
iPhone
須使用 iOS 7.1 或以上版本。
iPad
須使用 iPadOS 7.1 或以上版本。
iPod touch
須使用 iOS 7.1 或以上版本。
Climate tools支持意大利文, 英文

Climate tools相關應用

你可能還喜歡

Carel Industries s.r.l. 開發者的更多應用