Adiabatic Equation Calculator
Adiabatic Equation Formula
₩5,500Best Deal Ever
1.1.1for iPhone, iPad and more
Age Rating
Adiabatic Equation Calculator 스크린 샷
About Adiabatic Equation Calculator
Adiabatic Equation for calculating the minimum cpc (circuit protective conductor) and earth minimum csa sizes of earthing conductors.
No need to remember the complex adiabatic formula with this adiabatic calculator app for iPhone and iPad..
Adiabatic Equation Calculator takes into account of the following:
t = Disconnection time (seconds)
k = Conductor k value (From BS 7671 tables)
la = Fault current (PEFC in Amps)
I² = la x la
Values of K are obtained from the tables within BS 7671:
- Table 54.2 : Conductor not incorporated in a cable and not bunched with cables.
- Table 54.3 : Conductor incorporated in a cable or bunched with cables.
- Table 54.4 : Sheath or armour of a cable.
- Table 54.5 : Steel conduit or trunking.
Disconnection times (t) are obtained from the maximum operating time/current characteristics tables within BS 7671:
- Fig 3A2 (a,b) : BS 3036 semi-enclosed fuse
- Fig 3A3 : (a,b) : BS 88-2.2
- Fig 3A4 : BS EN 60898 / 61009-1 MCB/RCBO type B
- Fig 3A5 : BS EN 60898 / 61009-1 MCB/RCBO type C
- Fig 3A6 : BS EN 60898 / 61009-1 MCB/RCBO type D
- BS 1361 Fuse
How to use the Adiabatic Equation App:
1) Input your voltage value
2) Input your Zs value
3) Select protective device
4) Select protective device rating
5) Select conductor type
6) Select conductor material
7) Tap calculate
Adiabatic Equation Calculator Software / App for iPhone and iPad.
Check out our collection of electrical apps for iPad & iPhone
No need to remember the complex adiabatic formula with this adiabatic calculator app for iPhone and iPad..
Adiabatic Equation Calculator takes into account of the following:
t = Disconnection time (seconds)
k = Conductor k value (From BS 7671 tables)
la = Fault current (PEFC in Amps)
I² = la x la
Values of K are obtained from the tables within BS 7671:
- Table 54.2 : Conductor not incorporated in a cable and not bunched with cables.
- Table 54.3 : Conductor incorporated in a cable or bunched with cables.
- Table 54.4 : Sheath or armour of a cable.
- Table 54.5 : Steel conduit or trunking.
Disconnection times (t) are obtained from the maximum operating time/current characteristics tables within BS 7671:
- Fig 3A2 (a,b) : BS 3036 semi-enclosed fuse
- Fig 3A3 : (a,b) : BS 88-2.2
- Fig 3A4 : BS EN 60898 / 61009-1 MCB/RCBO type B
- Fig 3A5 : BS EN 60898 / 61009-1 MCB/RCBO type C
- Fig 3A6 : BS EN 60898 / 61009-1 MCB/RCBO type D
- BS 1361 Fuse
How to use the Adiabatic Equation App:
1) Input your voltage value
2) Input your Zs value
3) Select protective device
4) Select protective device rating
5) Select conductor type
6) Select conductor material
7) Tap calculate
Adiabatic Equation Calculator Software / App for iPhone and iPad.
Check out our collection of electrical apps for iPad & iPhone
Show More
최신 버전 1.1.1의 새로운 기능
Last updated on Jan 25, 2022
오래된 버전
Some optimisations and news feed update.
Show More
Version History
1.1.1
Jan 25, 2022
Some optimisations and news feed update.
1.1
Dec 7, 2021
Improved layout, reduced app download size & some optimizations.
1.0
May 5, 2020
Adiabatic Equation Calculator 가격
오늘:
₩5,500
최저 가격:
₩5,500
최고 가격:
₩6,000
Adiabatic Equation Calculator FAQ
제한된 국가 또는 지역에서 Adiabatic Equation Calculator를 다운로드하는 방법을 알아보려면 여기를 클릭하십시오.
Adiabatic Equation Calculator의 최소 요구 사항을 보려면 다음 목록을 확인하십시오.
iPhone
iOS 11.0 이상 필요.
iPad
iPadOS 11.0 이상 필요.
iPod touch
iOS 11.0 이상 필요.
Adiabatic Equation Calculator은 다음 언어를 지원합니다. 영어