Adiabatic Equation Calculator
Adiabatic Equation Formula
¥600Best Deal Ever
1.1.1for iPhone, iPad and more
Age Rating
Adiabatic Equation Calculator スクリーンショット
About Adiabatic Equation Calculator
Adiabatic Equation for calculating the minimum cpc (circuit protective conductor) and earth minimum csa sizes of earthing conductors.
No need to remember the complex adiabatic formula with this adiabatic calculator app for iPhone and iPad..
Adiabatic Equation Calculator takes into account of the following:
t = Disconnection time (seconds)
k = Conductor k value (From BS 7671 tables)
la = Fault current (PEFC in Amps)
I² = la x la
Values of K are obtained from the tables within BS 7671:
- Table 54.2 : Conductor not incorporated in a cable and not bunched with cables.
- Table 54.3 : Conductor incorporated in a cable or bunched with cables.
- Table 54.4 : Sheath or armour of a cable.
- Table 54.5 : Steel conduit or trunking.
Disconnection times (t) are obtained from the maximum operating time/current characteristics tables within BS 7671:
- Fig 3A2 (a,b) : BS 3036 semi-enclosed fuse
- Fig 3A3 : (a,b) : BS 88-2.2
- Fig 3A4 : BS EN 60898 / 61009-1 MCB/RCBO type B
- Fig 3A5 : BS EN 60898 / 61009-1 MCB/RCBO type C
- Fig 3A6 : BS EN 60898 / 61009-1 MCB/RCBO type D
- BS 1361 Fuse
How to use the Adiabatic Equation App:
1) Input your voltage value
2) Input your Zs value
3) Select protective device
4) Select protective device rating
5) Select conductor type
6) Select conductor material
7) Tap calculate
Adiabatic Equation Calculator Software / App for iPhone and iPad.
Check out our collection of electrical apps for iPad & iPhone
No need to remember the complex adiabatic formula with this adiabatic calculator app for iPhone and iPad..
Adiabatic Equation Calculator takes into account of the following:
t = Disconnection time (seconds)
k = Conductor k value (From BS 7671 tables)
la = Fault current (PEFC in Amps)
I² = la x la
Values of K are obtained from the tables within BS 7671:
- Table 54.2 : Conductor not incorporated in a cable and not bunched with cables.
- Table 54.3 : Conductor incorporated in a cable or bunched with cables.
- Table 54.4 : Sheath or armour of a cable.
- Table 54.5 : Steel conduit or trunking.
Disconnection times (t) are obtained from the maximum operating time/current characteristics tables within BS 7671:
- Fig 3A2 (a,b) : BS 3036 semi-enclosed fuse
- Fig 3A3 : (a,b) : BS 88-2.2
- Fig 3A4 : BS EN 60898 / 61009-1 MCB/RCBO type B
- Fig 3A5 : BS EN 60898 / 61009-1 MCB/RCBO type C
- Fig 3A6 : BS EN 60898 / 61009-1 MCB/RCBO type D
- BS 1361 Fuse
How to use the Adiabatic Equation App:
1) Input your voltage value
2) Input your Zs value
3) Select protective device
4) Select protective device rating
5) Select conductor type
6) Select conductor material
7) Tap calculate
Adiabatic Equation Calculator Software / App for iPhone and iPad.
Check out our collection of electrical apps for iPad & iPhone
Show More
最新バージョン 1.1.1 の更新情報
Last updated on 2022年01月25日
旧バージョン
Some optimisations and news feed update.
Show More
Version History
1.1.1
2022年01月25日
Some optimisations and news feed update.
1.1
2021年12月07日
Improved layout, reduced app download size & some optimizations.
1.0
2020年05月05日
Adiabatic Equation Calculator 価格
今日:
¥600
最低価格:
¥600
最高価格:
¥650
Adiabatic Equation Calculator FAQ
ここをクリック!地理的に制限されているアプリのダウンロード方法をご参考ください。
次のリストをチェックして、Adiabatic Equation Calculatorの最低システム要件をご確認ください。
iPhone
iOS 11.0以降が必要です。
iPad
iPadOS 11.0以降が必要です。
iPod touch
iOS 11.0以降が必要です。
Adiabatic Equation Calculatorは次の言語がサポートされています。 英語