Adiabatic Equation Calculator
Adiabatic Equation Formula
USD 3.99
1.1.1for iPhone, iPad and more
Age Rating
لقطات الشاشة لـ Adiabatic Equation Calculator
About Adiabatic Equation Calculator
Adiabatic Equation for calculating the minimum cpc (circuit protective conductor) and earth minimum csa sizes of earthing conductors.
No need to remember the complex adiabatic formula with this adiabatic calculator app for iPhone and iPad..
Adiabatic Equation Calculator takes into account of the following:
t = Disconnection time (seconds)
k = Conductor k value (From BS 7671 tables)
la = Fault current (PEFC in Amps)
I² = la x la
Values of K are obtained from the tables within BS 7671:
- Table 54.2 : Conductor not incorporated in a cable and not bunched with cables.
- Table 54.3 : Conductor incorporated in a cable or bunched with cables.
- Table 54.4 : Sheath or armour of a cable.
- Table 54.5 : Steel conduit or trunking.
Disconnection times (t) are obtained from the maximum operating time/current characteristics tables within BS 7671:
- Fig 3A2 (a,b) : BS 3036 semi-enclosed fuse
- Fig 3A3 : (a,b) : BS 88-2.2
- Fig 3A4 : BS EN 60898 / 61009-1 MCB/RCBO type B
- Fig 3A5 : BS EN 60898 / 61009-1 MCB/RCBO type C
- Fig 3A6 : BS EN 60898 / 61009-1 MCB/RCBO type D
- BS 1361 Fuse
How to use the Adiabatic Equation App:
1) Input your voltage value
2) Input your Zs value
3) Select protective device
4) Select protective device rating
5) Select conductor type
6) Select conductor material
7) Tap calculate
Adiabatic Equation Calculator Software / App for iPhone and iPad.
Check out our collection of electrical apps for iPad & iPhone
No need to remember the complex adiabatic formula with this adiabatic calculator app for iPhone and iPad..
Adiabatic Equation Calculator takes into account of the following:
t = Disconnection time (seconds)
k = Conductor k value (From BS 7671 tables)
la = Fault current (PEFC in Amps)
I² = la x la
Values of K are obtained from the tables within BS 7671:
- Table 54.2 : Conductor not incorporated in a cable and not bunched with cables.
- Table 54.3 : Conductor incorporated in a cable or bunched with cables.
- Table 54.4 : Sheath or armour of a cable.
- Table 54.5 : Steel conduit or trunking.
Disconnection times (t) are obtained from the maximum operating time/current characteristics tables within BS 7671:
- Fig 3A2 (a,b) : BS 3036 semi-enclosed fuse
- Fig 3A3 : (a,b) : BS 88-2.2
- Fig 3A4 : BS EN 60898 / 61009-1 MCB/RCBO type B
- Fig 3A5 : BS EN 60898 / 61009-1 MCB/RCBO type C
- Fig 3A6 : BS EN 60898 / 61009-1 MCB/RCBO type D
- BS 1361 Fuse
How to use the Adiabatic Equation App:
1) Input your voltage value
2) Input your Zs value
3) Select protective device
4) Select protective device rating
5) Select conductor type
6) Select conductor material
7) Tap calculate
Adiabatic Equation Calculator Software / App for iPhone and iPad.
Check out our collection of electrical apps for iPad & iPhone
Show More
تحديث لأحدث إصدار 1.1.1
Last updated on 25/01/2022
الإصدارات القديمة
Some optimisations and news feed update.
Show More
Version History
1.1.1
25/01/2022
Some optimisations and news feed update.
1.1
07/12/2021
Improved layout, reduced app download size & some optimizations.
1.0
05/05/2020
Adiabatic Equation Calculator FAQ
انقر هنا لمعرفة كيفية تنزيل Adiabatic Equation Calculator في بلد أو منطقة محظورة.
تحقق من القائمة التالية لمعرفة الحد الأدنى من المتطلبات Adiabatic Equation Calculator.
iPhone
Requiere iOS 11.0 o posterior.
iPad
Requiere iPadOS 11.0 o posterior.
iPod touch
Requiere iOS 11.0 o posterior.
Adiabatic Equation Calculator هي مدعومة على اللغات Inglés